JMAR Technologies Marketing Communications Manager Kathi Kirchmeier, 858-946-6800 kkirchmeier@jmar.com or Investor Relations Intl Managing Partner Haris Tajyar, 818-382-9702 htajyar@irintl.com JMAR Technologies, Inc. (OTCBB:JMAR), a leading developer of advanced laser, photonics and detection technologies, today announced the results of a testing program carried out by the U.S. Environmental Protection Agency (EPA) to measure the performance of
JMAR's BioSentry monitoring system and competing products at detecting harmful microorganisms in drinking water distribution systems.
The U.S. EPA presented results at the AWWA Water Security Congress 2008 this week and the tests found that BioSentry was able to detect bacterial pathogens up to 25 times better than any other product tested. The published results can be found in the proceedings of the conference.
The program was carried out in 2007 by the EPA's National Security Homeland Research Center, using a pilot-scale water distribution system at the EPA's testing and evaluation facility in Cincinnati, Ohio. Tests were performed to determine the detection capabilities of BioSentry and other products against intentional introduction of pathogens into a water distribution system. Several pathogen surrogates were used simulating lethal microbes.
JMAR Technologies' President and CEO C. Neil Beer, Ph.D., commented, "As a matter of policy, the EPA does not endorse or promote specific products. However, the performance of our flagship product, BioSentry, in EPA's strictly objective testing program, speaks for itself. These results strongly reinforce our conviction that BioSentry will soon be in wide use around the world to protect the public from intentional or accidental contamination of water supplies. The success of BioSentry also bodes well for other products in development that employ similar advanced technology."
To be added to JMAR Technologies' investor lists, please contact Haris Tajyar at htajyar@irintl.com or at 818-382-9702.
About JMAR
JMAR Technologies, Inc. (OTCBB:JMAR) is a late-stage technology company with expertise in the development and early commercialization of detection and laser-based technologies for nano-scale imaging, chemical and biological analysis, and fabrication. The Company is leveraging more than a decade of laser and photonics research in developing a portfolio of products with market applications in high interest areas such as homeland security, biological monitoring of water quality, and hazardous materials detection. These technologies represent significant intellectual property, including twenty nine issued or pending patents. For further information on JMAR Technologies, please visit www.jmar.com.
Forward Looking Statements: This news release contains certain "forward-looking statements." Forward-looking statements are based on current expectations and assumptions and are inherently subject to risks and uncertainties, some of which cannot be predicted or quantified, and many of which are beyond the Company's control. Actual results could differ materially from these forward-looking statements as a result of a number of factors, including the uncertainty of acceptance in the market for our products and technologies or the acceptance of our customers' products or technologies which incorporate our products and technologies, the failure of our technology to perform as predicted, competition from alternative technologies, uncertainties as to the size of the markets, cost and margins for JMAR's products, current or future government regulations affecting the use of JMAR's products, the lack of availability of critical components, the degree of protection from future patents, other risks associated with the development or acquisition of new products or technologies and those risks detailed in the Company's Form 10-K for the year ended December 31, 2007 filed with the SEC. Given these risks and uncertainties, investors are cautioned not to place undue reliance on such forward-looking statements and no assurances can be given that such statements will be achieved. JMAR Technologies, Inc. does not assume any duty to publicly update or revise the material contained herein.
Product Outperforms All Alternative Technologies for Real-Time
Pathogen Detection
Sunday, April 13, 2008
NDSU, other land grant universities join to develop eXtension web site
The North Dakota State University Extension Service has teamed up with 73 other universities to develop eXtension, a Web site devoted to bringing solutions to today's complex challenges. The information-packed Web site can be accessed at http://www.extension.org/.
eXtension is a portal to the nation's largest educational and information system, its creators say. It provides reliable answers based on solid research and trustworthy, field-tested data, along with the knowledge of experts from land-grant universities across the nation. It complements and enhances the community-based programming the Extension Service provides.
Topics covered on the eXtension Web site include horticulture, personal finance, parenting, family issues, horses, beef and dairy cattle, entrepreneurship, geospatial technology, dealing with disasters, cotton, diversity, fire ants, wildlife damage and management, and a program that exposes youth to science, engineering and technology. More topics will be added in the coming months.
“I am excited to be involved in developing this resource because it will provide access to timely, unbiased and accurate information for consumers 24/7,” says Debra Pankow, NDSU Extension Service family economics specialist. Pankow chairs the group that gathers information on financial security.
eXtension provides information a number of ways, including articles from resource area experts and answers to frequently asked questions. However, unlike most other Web-based information resources, eXtension also has experts from universities throughout the country ready to answer specific questions within 48 hours. Once answered, the question and answer become part of the frequently answered questions section of a topic.
Source: NDSU Extension
eXtension is a portal to the nation's largest educational and information system, its creators say. It provides reliable answers based on solid research and trustworthy, field-tested data, along with the knowledge of experts from land-grant universities across the nation. It complements and enhances the community-based programming the Extension Service provides.
Topics covered on the eXtension Web site include horticulture, personal finance, parenting, family issues, horses, beef and dairy cattle, entrepreneurship, geospatial technology, dealing with disasters, cotton, diversity, fire ants, wildlife damage and management, and a program that exposes youth to science, engineering and technology. More topics will be added in the coming months.
“I am excited to be involved in developing this resource because it will provide access to timely, unbiased and accurate information for consumers 24/7,” says Debra Pankow, NDSU Extension Service family economics specialist. Pankow chairs the group that gathers information on financial security.
eXtension provides information a number of ways, including articles from resource area experts and answers to frequently asked questions. However, unlike most other Web-based information resources, eXtension also has experts from universities throughout the country ready to answer specific questions within 48 hours. Once answered, the question and answer become part of the frequently answered questions section of a topic.
Source: NDSU Extension
DuPont, USDA ARS to collaborate on new E. coli test in beef
DuPont and the United States Department of Agriculture Agricultural Research Service (ARS) are teaming up to find new ways to detect an E. coli strain in beef that, even in low concentrations, can cause severe illness.
Through a cooperative research and development agreement, the U.S. Meat Animal Research Center (USMARC) at Clay Center, Neb., and DuPont Qualicon will develop a new test for E. coli 0157:H7, a pathogen that led to more than 30 million pounds of ground beef being recalled in 2007.
“Our mission is to develop scientific information and new technology to solve high priority problems for the U.S. beef, sheep and swine industries,” Mohammad Koohmaraie, USMARC director, said. “In the case of E. coli O157:H7 detection, we're looking at collaborative ways to quickly develop a new test.”
“We are committed to providing the meat industry with testing applications that use the best science available. This agreement allows us to work with experts from the USDA ARS toward our common goal of an E. coli O157:H7 test that is even faster, more accurate and more efficient,” Kevin Huttman, president,DuPont Qualicon, said.
E. coli O157:H7 is a food borne pathogen usually associated with eating undercooked, contaminated ground beef. Even in low concentrations, it can cause severe illness, sometimes leading to hemolytic uremic syndrome (HUS) and kidney failure in at-risk populations.
After several years of declining incidence, 2007 saw a resurgence with more than 30 million pounds of ground beef recalled due to possible E. coli O157:H7 contamination.
The DuPont Qualicon BAX system is currently used by food companies and governments around the world to reliably detect pathogens in food, including E. coli O157:H7, Salmonella, Listeria and more.
Through a cooperative research and development agreement, the U.S. Meat Animal Research Center (USMARC) at Clay Center, Neb., and DuPont Qualicon will develop a new test for E. coli 0157:H7, a pathogen that led to more than 30 million pounds of ground beef being recalled in 2007.
“Our mission is to develop scientific information and new technology to solve high priority problems for the U.S. beef, sheep and swine industries,” Mohammad Koohmaraie, USMARC director, said. “In the case of E. coli O157:H7 detection, we're looking at collaborative ways to quickly develop a new test.”
“We are committed to providing the meat industry with testing applications that use the best science available. This agreement allows us to work with experts from the USDA ARS toward our common goal of an E. coli O157:H7 test that is even faster, more accurate and more efficient,” Kevin Huttman, president,DuPont Qualicon, said.
E. coli O157:H7 is a food borne pathogen usually associated with eating undercooked, contaminated ground beef. Even in low concentrations, it can cause severe illness, sometimes leading to hemolytic uremic syndrome (HUS) and kidney failure in at-risk populations.
After several years of declining incidence, 2007 saw a resurgence with more than 30 million pounds of ground beef recalled due to possible E. coli O157:H7 contamination.
The DuPont Qualicon BAX system is currently used by food companies and governments around the world to reliably detect pathogens in food, including E. coli O157:H7, Salmonella, Listeria and more.
Labels:
0157:H7,
beef,
Dupont Qualicon,
e. coli,
new technologies
Avian Biosecurity Technology Development Fund
Canada’s New Government has committed a total of $3 million in funding over five years for avian biosecurity-related projects. The Avian Biosecurity Technology Development Fund was established in 2006 to provide assistance to eligible recipients to develop or advance on-farm biosecurity technologies of interest to the Canadian poultry sector.
Biosecurity refers to measures that protect the health of livestock by preventing transmission of disease. It is the most important investment industry can make to limit opportunities for the introduction and spread of avian influenza and other infectious diseases in their flock.
Eligible projects are selected based on essential criteria, under the categories of Technology Development, Technology Acceleration and Technology Demonstration. The Fund is managed by the Office of Animal Biosecurity of the Canadian Food Inspection Agency (CFIA).
Seven projects were selected for funding for the 2006/2007 fiscal year, with a total investment of $500,000. Those projects include:
Study of Microbial Contaminants on Shell Egg Conveyance Equipment
Canadian Egg Marketing Agency
This study will evaluate the risk of contamination of conveyance equipment used in production units and hatcheries, in grading stations and processing plants, and in transit. The goal is to develop acceptable, national protocols for cleaning and disinfecting trays, carts, and plastic skids/dividers. Proper equipment, which meets or exceeds the objectives of these protocols, will also be recommended.
Biosecurity Teaching Facility
University of Alberta
The Poultry Research Centre (PRC) of the University of Alberta is updating teaching materials and training facilities for its biosecurity program. Activities include:
the development of manuals outlining a complete biosecurity program, including a detailed account of retrofitting existing facilities with improved biosecurity measures; and,
the development of training activities and learning tools to disseminate the project results - including an industry workshop, training sessions for PRC users, and short educational videos about on-farm biosecurity.
The concepts and practices that are being developed through this study are intended to provide practical knowledge that can be adopted by both students and industry.
Anterooms for Existing Poultry Barns
eBiz Professionals Inc.
This project involves the design and construction of new anterooms (entrance ways) for existing poultry barns on farms in British Columbia and Ontario. Funding has been granted for the design and construction of four anterooms – three in British Columbia and one in Ontario.
Enhanced Equipment for Poultry Catching Crews
eBiz Professionals Inc.
Gates and fences are used by catchers to contain poultry when they are being collected for transportation. Units are often transported between farms, thus posing a significant risk for disease transmission. This project includes the design and development of four different prototypes for gates and fences that can remain on poultry farms. The goal is to develop a unit that can be mass-produced at a reasonable cost, and can be properly cleaned and stored on location. The intention is to help eliminate the risk of disease transmission from farm-to-farm.
Crate Washing Systems
eBiz Professionals Inc.
Crate washers are used in the receiving area of poultry processing plants to ensure that crates, which are used to transport poultry from farm-to-farm, are thoroughly cleaned and remain free of contaminated material. This project will examine a range of crate-washing systems and determine areas for improvement. With the assistance of processing personnel and equipment suppliers, design concepts for new systems will be developed and new prototypes built.
Chemical Fogger
Canards du lac Brome Ltée.
A chemical fogger for disinfecting poultry premises will be installed and tested on the grounds of a duck breeding operation. The goal is to heighten preventative measures against the infection of high-risk diseases among poultry by enhancing disinfection and sanitizing techniques, by use of the chemical fogger.
Plastic Nests for Commercial Waterfowl Production Facility
King Cole Ducks Limited
Pathogenic micro-organisms, such as salmonella, commonly contaminate newly-laid eggs in waterfowl species. This project will examine the efficacy of plastic nest boxes in lowering the presence of micro-organisms, in comparison with traditional wooden nest boxes.
All recipients of funding through the Avian Biosecurity Technology Development Fund are required to submit a final report to the CFIA regarding the outcome of their respective project(s). Under the agreement, any new technologies, techniques and protocols that are developed and approved must be published and shared with the Canadian poultry industry for widespread use.
For more information on the Avian Biosecurity Technology Development Fund and the above mentioned projects, please contact:
Dr. Keith G. Campbell
National Manager, Office of Animal Biosecurity
Canadian Food Inspection Agency
613-221-3913
campbellkg@inspection.gc.ca
Biosecurity refers to measures that protect the health of livestock by preventing transmission of disease. It is the most important investment industry can make to limit opportunities for the introduction and spread of avian influenza and other infectious diseases in their flock.
Eligible projects are selected based on essential criteria, under the categories of Technology Development, Technology Acceleration and Technology Demonstration. The Fund is managed by the Office of Animal Biosecurity of the Canadian Food Inspection Agency (CFIA).
Seven projects were selected for funding for the 2006/2007 fiscal year, with a total investment of $500,000. Those projects include:
Study of Microbial Contaminants on Shell Egg Conveyance Equipment
Canadian Egg Marketing Agency
This study will evaluate the risk of contamination of conveyance equipment used in production units and hatcheries, in grading stations and processing plants, and in transit. The goal is to develop acceptable, national protocols for cleaning and disinfecting trays, carts, and plastic skids/dividers. Proper equipment, which meets or exceeds the objectives of these protocols, will also be recommended.
Biosecurity Teaching Facility
University of Alberta
The Poultry Research Centre (PRC) of the University of Alberta is updating teaching materials and training facilities for its biosecurity program. Activities include:
the development of manuals outlining a complete biosecurity program, including a detailed account of retrofitting existing facilities with improved biosecurity measures; and,
the development of training activities and learning tools to disseminate the project results - including an industry workshop, training sessions for PRC users, and short educational videos about on-farm biosecurity.
The concepts and practices that are being developed through this study are intended to provide practical knowledge that can be adopted by both students and industry.
Anterooms for Existing Poultry Barns
eBiz Professionals Inc.
This project involves the design and construction of new anterooms (entrance ways) for existing poultry barns on farms in British Columbia and Ontario. Funding has been granted for the design and construction of four anterooms – three in British Columbia and one in Ontario.
Enhanced Equipment for Poultry Catching Crews
eBiz Professionals Inc.
Gates and fences are used by catchers to contain poultry when they are being collected for transportation. Units are often transported between farms, thus posing a significant risk for disease transmission. This project includes the design and development of four different prototypes for gates and fences that can remain on poultry farms. The goal is to develop a unit that can be mass-produced at a reasonable cost, and can be properly cleaned and stored on location. The intention is to help eliminate the risk of disease transmission from farm-to-farm.
Crate Washing Systems
eBiz Professionals Inc.
Crate washers are used in the receiving area of poultry processing plants to ensure that crates, which are used to transport poultry from farm-to-farm, are thoroughly cleaned and remain free of contaminated material. This project will examine a range of crate-washing systems and determine areas for improvement. With the assistance of processing personnel and equipment suppliers, design concepts for new systems will be developed and new prototypes built.
Chemical Fogger
Canards du lac Brome Ltée.
A chemical fogger for disinfecting poultry premises will be installed and tested on the grounds of a duck breeding operation. The goal is to heighten preventative measures against the infection of high-risk diseases among poultry by enhancing disinfection and sanitizing techniques, by use of the chemical fogger.
Plastic Nests for Commercial Waterfowl Production Facility
King Cole Ducks Limited
Pathogenic micro-organisms, such as salmonella, commonly contaminate newly-laid eggs in waterfowl species. This project will examine the efficacy of plastic nest boxes in lowering the presence of micro-organisms, in comparison with traditional wooden nest boxes.
All recipients of funding through the Avian Biosecurity Technology Development Fund are required to submit a final report to the CFIA regarding the outcome of their respective project(s). Under the agreement, any new technologies, techniques and protocols that are developed and approved must be published and shared with the Canadian poultry industry for widespread use.
For more information on the Avian Biosecurity Technology Development Fund and the above mentioned projects, please contact:
Dr. Keith G. Campbell
National Manager, Office of Animal Biosecurity
Canadian Food Inspection Agency
613-221-3913
campbellkg@inspection.gc.ca
Labels:
biosecurity,
Canadian Food Inspection Agency,
funding,
poultry
Wednesday, February 6, 2008
‘Bio-security’ measures launched
Around 800 more chickens died on Saturday in a poultry farm reportedly owned by the Rangers. The farm is located adjacent to the one in which Friday’s laboratory test confirmed the outbreak of the H5N1 strain of bird flu. The discovery compelled officials to put nine people, including four Rangers’ personnel under observation, Health officials said.
“The adjacent poultry farm is being monitored, though its laboratory test is expected on Monday,” said Deputy Secretary Health Dr Shakil Mullick.
According to him, teams of doctors have examined over 50 people and no human infection case has so far been detected. Nine poultry workers associated with the adjacent farm are being monitored by doctors twice a day - morning and evening. Three workers of “Uni Poultry Farm” have been kept at the isolation ward of the Civil Hospital, Karachi.
Doctors visited five more poultry farms on Saturday and examined over 20 workers. However, nothing unusual was found.
Health Officer (Gadap Town) Khalil Ansari said that the death of more birds at the adjacent farm has given rise to the suspicion of the existence of bird flu. Hence, he said, they have started spraying there. According to him, the workers have been given masks, gloves, etc. as precautionary measures. Furthermore, three surveillance teams have been formed, which are visiting the farms, besides which doctors are also examining the family members of the affected poultry workers. Ansari mentioned that they were facing some resistance at various poultry farms but added that the town administration managed to resolve the matter.
He said that, so far, 2,500 chickens, among 5,000, had died at the adjacent farm.
Dr Rasheed Ahmed Bhutto, a member of the three teams of doctors set up by Provincial Coordination on Bird Flu, told The News that they have started “bio-security” measures to prevent spread of bird flu. They visited around 10 to 12 poultry farms and informed the owners about the bio-security steps, he said, adding that one team of doctors would be regularly visiting the area from Sunday.
Elaborating, he said that the bio-security measures pertain to covering feed and water as well as burying birds and not visiting infected farms. He mentioned that each farm in Dhunba Goth contains around 15,000 to 30,000 chickens.
Provincial Coordinator on Bird Flu, Dr Ali Akbar Soomro, said that they had taken samples from a couple of poultry farms as precautionary measures. According to him, migratory birds, improper management of farms, lack of clean water and polluted feed were the major causes of this outbreak. Safe water could control the outbreak of virus up to 50 per cent and proper nutrients could increase resistance power in birds up to 20-22 per cent, he added.
He, however, dispelled the impression of the existence of bird flu in Hyderabad, Thatta and Badin, adding that reports were sought from the EDOs after hearing the news but all of them rejected the same. —IA
Source:- The News,Pakistan
“The adjacent poultry farm is being monitored, though its laboratory test is expected on Monday,” said Deputy Secretary Health Dr Shakil Mullick.
According to him, teams of doctors have examined over 50 people and no human infection case has so far been detected. Nine poultry workers associated with the adjacent farm are being monitored by doctors twice a day - morning and evening. Three workers of “Uni Poultry Farm” have been kept at the isolation ward of the Civil Hospital, Karachi.
Doctors visited five more poultry farms on Saturday and examined over 20 workers. However, nothing unusual was found.
Health Officer (Gadap Town) Khalil Ansari said that the death of more birds at the adjacent farm has given rise to the suspicion of the existence of bird flu. Hence, he said, they have started spraying there. According to him, the workers have been given masks, gloves, etc. as precautionary measures. Furthermore, three surveillance teams have been formed, which are visiting the farms, besides which doctors are also examining the family members of the affected poultry workers. Ansari mentioned that they were facing some resistance at various poultry farms but added that the town administration managed to resolve the matter.
He said that, so far, 2,500 chickens, among 5,000, had died at the adjacent farm.
Dr Rasheed Ahmed Bhutto, a member of the three teams of doctors set up by Provincial Coordination on Bird Flu, told The News that they have started “bio-security” measures to prevent spread of bird flu. They visited around 10 to 12 poultry farms and informed the owners about the bio-security steps, he said, adding that one team of doctors would be regularly visiting the area from Sunday.
Elaborating, he said that the bio-security measures pertain to covering feed and water as well as burying birds and not visiting infected farms. He mentioned that each farm in Dhunba Goth contains around 15,000 to 30,000 chickens.
Provincial Coordinator on Bird Flu, Dr Ali Akbar Soomro, said that they had taken samples from a couple of poultry farms as precautionary measures. According to him, migratory birds, improper management of farms, lack of clean water and polluted feed were the major causes of this outbreak. Safe water could control the outbreak of virus up to 50 per cent and proper nutrients could increase resistance power in birds up to 20-22 per cent, he added.
He, however, dispelled the impression of the existence of bird flu in Hyderabad, Thatta and Badin, adding that reports were sought from the EDOs after hearing the news but all of them rejected the same. —IA
Source:- The News,Pakistan
GE to purchase Whatman for $717M
Published: Tuesday, February 05, 2008
General Electric Co. agreed to buy Whatman Plc, the U.K. maker of DNA-based products for drug research and police laboratories, for 363 million pounds ($717 million) to gain filters and equipment for its health-care business.
Investors in London-based Whatman will get 270 pence a share, Fairfield, Conn.-based GE said Monday in a statement. That's 12 percent more than Whatman's closing price on Feb. 1, the last trading day before Monday's announcement, and 31 per cent more than the closing price on Jan. 14, the day before Whatman announced it had been approached as a target.
Source: The Calgary Herald
02/06/08
General Electric Co. agreed to buy Whatman Plc, the U.K. maker of DNA-based products for drug research and police laboratories, for 363 million pounds ($717 million) to gain filters and equipment for its health-care business.
Investors in London-based Whatman will get 270 pence a share, Fairfield, Conn.-based GE said Monday in a statement. That's 12 percent more than Whatman's closing price on Feb. 1, the last trading day before Monday's announcement, and 31 per cent more than the closing price on Jan. 14, the day before Whatman announced it had been approached as a target.
Source: The Calgary Herald
02/06/08
Labels:
acquisitions,
green investments,
green technology
Wednesday, January 2, 2008
Greening the Caribbean
In Puerto Rico, engineers integrate commonly used technologies to produce a unique top-rated green building.
Standard Refrigeration Co. Inc.'s Guaynabo, Puerto Rico, facility was getting old. Real estate costs were skyrocketing. The shared office and manufacturing space just wasn't cutting it any more. The mechanical/electrical contracting firm, founded 60 years ago, had to move.
But firm officials didn't want just to build a new facility—they wanted a unique, sustainable building. The firm decided to acquire 5 acres of industrial set-aside land on the outskirts of San Juan. They acquired land in 1999, and completed the permit acquisition in 2004. Construction of the administrative building began in 2005, with occupancy beginning in 2006.
Finally, the crowning glory of the project came on Sept. 21, 2006, when the facility achieved a platinum rating under USGBC LEED NC Version 2.1 for new construction—the first building in Puerto Rico, and the first in the Caribbean, to attain this highest LEED certification level.
“The greatest challenge on the project was complying with requirements for LEED platinum status,” said Jorge Ledon Webster, PE, lead mechanical engineer on the project. “A lot of effort was put into providing a first-class interior environment requiring minimal energy costs. The LEED process requires a lot of documentation.”
The two-story building is a 9,600-sq.-ft footprint with 12,000 sq. ft of air conditioned area for offices, cafeteria and storage areas. In addition to being designed to LEED NC Version 2 requirements, the design process also adhered to ASHRAE 90.1-1999 for energy efficiency, ASHRAE 55-1995 for thermal comfort for human occupancy, and ASHRAE 62.1-2001 standard for ventilation. The main incentive for the new building was to achieve a substantial energy use reduction when compared with the firm's existing facility in Guaynabo.
Conserving energy
Energy conservation measures incorporated into the design including:
Lighting upgrade: With an illumination-level calculation program, and using minimum illumination level requirements of 50 lumens at all desktops, the total Watts per square foot were reduced by 0.78 W/sq. ft. In addition, all offices and open areas have T8 lamps with high-efficiency tubes and occupancy sensors. All walls have a reflectivity of 75% and ceilings have a reflectivity of 85%.
Insulation upgrade: In addition to the minimum requirements of ASHRAE 90.1-1999, the roof insulation was increased from R19 to R30 with a reflectivity of 92% and the walls from U = 0.58 and no R value requirement to a U = 0.089 and an R11.25.
Condensing unit efficiency upgrade: R410A units with dual speed compressors and 60,000 Btuh capacity with an 11.35 EER were installed (ASHRAE 90.1 minimum requirement is 9.7 EER).
Heat recovery: An energy recovery unit (enthalpy wheel) with an 85% efficiency and capable of handling 125% of the required outside air was included in the system. In addition, the hot water for the reheat coil in the air conditioning units is obtained from desuperheaters for each of four compressors. Solar panels are connected in series for additional reheat capacity.
High efficiency fans: The air conditioning unit has an adjustable-pitch vane axial fan with a static efficiency greater than 75%. ASHRAE 90.1 requires a maximum of 1.7 hp per 1,000 cfm for variable air volume (VAV) systems. The design used 0.675 hp per 1,000 cfm.
Fenestration: Double glass windows with clear glass inside and low-E glass outside with U = 0.26, exceeding ASHRAE 90.1 requirements. In addition, exterior metal shadings cover all glass areas for a substantial improvement on the solar heat gain coefficient requirements.
Exhaust and supply fans: The building exhaust and the outside air make-up use the fans of the energy recovery unit and are both served by variable frequency drives for higher energy efficiencies. Electrical efficiencies
“Our new building consumes so much less electricity than our previous building that the electrical savings alone will pay for the cost of the new building in 10 to 15 years at today's electricity rates,” said Juan S. Quintana, president of Standard Refrigeration. Strategies employed in this project yielded the results for electricity usage shown in Table 1.
Using the LEED-NC Version 2.1 criteria, where receptacles are not considered, the electricity savings is in excess of 70% when compared with ASHRAE 90.1-1999. The building management system of the new facility, along with a separate energy monitoring system, provided the electricity use data shown in Table 2. For the period from July 15, 2006, to July 15, 2007, the results of a comparison between design and actual use are shown in Table 3.
The hours of use and the square footage used in the model defined the difference in design vs. actual use of electricity for the receptacles. The complete building area should have been used in design for the receptacles rather than the air conditioned areas. The building receptacles serve refrigerators, water coolers, vending machines, uninterruptible power supplies, photocopiers, and other electrical units that consume electricity 24 hours per day.
For receptacles design: 12,000 sq. ft x 2,496 h x 0.66 W/sq. ft = 19,768 kWh
For receptacles actual: 19,200 sq. ft x 8,760 h x 0.29 W/sq. ft = 48,776 kWh.
The actual number of hours increased because they had to start up the unit two hours earlier every day, used the unit during the lunch hour, and used it for two additional hours every day in the afternoon, which lead to the difference between design and actual electricity use for the air conditioning system. The number of hours used in the design model is 2,496, but the actual number of hours is 4,400: 4,400/2,496 x 51,885 kWh = 91,464 kWh
Mechanical integration
The air conditioning system consists of an air-handling unit (AHU) with a VAV adjustable-pitch vane axial fan with variable volume boxes to maintain static pressure and variable volume diffusers in every location. The AHU has a DX cooling coil that is vertically split intertwined and has a double circuit, top and bottom. The AHU is a draw-through type, and each coil section closest to the fan has an individual 5 TR (tons of refrigeration) condensing unit connected to it that runs continuously while the fan is operating. Each of the other coil sections of the split coil is connected to a variable speed 5 TR condensing unit and responds to leaving air temperature (set at 53 F).
The variable speed condensing units are not allowed to cycle more than six times per hour. If the building temperature drops below 73 F, the VAV reheat water pump operates to raise the building return air temperature through the reheat coil. This combination of sequences allows the A/C system to maintain 72 F +/-1 F and 50% +/-5% relative humidity.
Outside air is forced into the AHU return plenum by a VAV energy recovery unit that is capable of 125% of the required air for ventilation. The AHU has (MERV 14) 85% efficient permanent filters and 40% throw away pre-filters. It also has UV-C lights in the return air plenum using the intensity recommendations from “Immune Building Systems Technology” (Wladyslaw Jan Kowalski, McGraw-Hill, 2002).
All ductwork in the building is galvanized sheet metal double-wall with solid interior liner and fiberglass insulation sandwiched between duct walls. Additionally, the inner duct liner is covered with a technology that liberates silver ions and prevents bacterial growth inside the ducts.
All VAV diffusers (thermafusers) were placed so as to achieve an air diffusion performance index of 90 or greater. Areas with more than one occupant have a thermostat that can bypass the VAV serving the area and convert the VAV to temperature-controlled for a period of 3 hours. A Web-based monitoring system samples seven different areas of the building for temperature, relative humidity, carbon monoxide, carbon dioxide, VOCs, and particulate. This continuous sampling process also reports to the energy management system.
In order to verify the particulate reported by the monitoring system, the engineers brought in a particle counter and the area sampled at random reported as ISO class 8 clean room. The ratio is maintained at a maximum of 1.0 cfm/sq. ft and a minimum of 0.7 cfm/sq. ft by the VAV system. The ratio of exhaust air to intake air is controlled using VAV units in both supply and exhaust fans to achieve positive building pressurization, adequate exhaust control, and minimum ventilation requirements at all times. Only if the carbon monoxide in the building exceeds 800 parts per million will the minimum ventilation rate be exceeded while always maintaining building pressurization.
Not only did the design team create a high-performance facility in terms of energy efficiency, but they also maximized efficiencies with respect to operation and maintenance. The AHU, energy recovery unit, condensing units, desuperheaters, reheat water tank, reheat pump and domestic solar hot water collectors all are located on a single pad outside the building for ease of maintenance. And the commissioning process verified each and every item of the HVAC and plumbing system.
Design uniqueness
“The positive environmental impacts that result from the design of our new building are significant and many,” Quintana said, “including condensing units that use R-410A refrigerant; electrical savings of 70% that substantially reduce carbon dioxide generation; and recycling of materials such as glass, paper, aluminum, cardboard, electrical lamps, printer cartridges, car batteries, oil, cellular phones, sheet metal, car tires, wood pallets, and grass.”
In addition, light pollution is eliminated by keeping the illumination within the site; all storm water is strained for removal of oil residue and some phosphorus; rain water is used for toilets and urinals; and the facility's own sewage treatment plant operates on evapotranspiration, which does not impact acquifer recharging. Storm water is retained in an underground rechargeable tank that slowly releases water during a 72 h timeframe so that water will not affect the level of the creek close to our site.
“We feel that our building is really unique,” Quintana said. “It is located in Puerto Rico without the benefits of using cold outside air for air conditioning at any time during the year. Yet still, we have achieved 750 sq. ft/ton.
“The greatest reward was that project goals were accomplished, and that the owner obtained substancial savings from energy and water measures that were implemented during the design process,” he said. “The coordination between the owner, which in this case was the contractor, and the rest of the design team was a great plus for implementing all the energy savings into the project.”
Because the owners of the facility are in the MEP business themselves, they began this project with a strong notion of what could be achieved, and challenged their design team with the task of far surpassing their existing building in energy use reduction. And the design team did a “platinum” job of meeting the challenge.
End use Design case (kWh) Budget case (kWh)
Electrical receptacles 19,740 19,740
Lighting 29,823 48,232
Space cooling 42,168 116,703
Fans/pumps 9,717 110,028
Date Receptacles First floor Second floor A/C
07/15/2006 40 x 106 W 6 x 106 W 6 x 106 W 44 x 106 W
07/15/2007 88 x 106 W 17 x 106 W 18 x 106 W 83.5 x 106 W
Use Design (kWh) Actual (kWh)
Lighting 29,823 23,000
Receptacles 19,740 48,000
A/C 51,885 83,500
Natural ventilation makes this library coolest building on campus
Architecture rules at this new Judson University building, which houses an expanded library and the division of art, design, and architecture. “Seeking a facility worthy of an evolving architecture program that is seeking accreditation, the university conducted an international design competition,” said Norm Bower, KJWW public relations coordinator. London-based architect Alan Short of Short and Assocs., a pioneer in low-energy, naturally ventilated, and passively cooled buildings, designed the facility.
The design team's challenge was to treat light and humidity issues in a library and art environment, where these factors could seriously damage the contents of the 88,000-sq.-ft building. Dominant energy-conscious features of the building are its photovoltaic, natural ventilation, and natural daylighting systems. Optimizing solar gains in the spring and fall is intended to allow the building to run naturally, with little or no mechanical intervention, for six or more months of the year. The building is expected to earn a USGBC LEED silver rating.
“The greatest challenge as an HVAC engineer on this project was taking the vision of placing a naturally ventilated building in the middle of the Midwest,” said Wade Ross, PE, lead mechanical engineer on the project. “Although the system works well in Northern Europe, we had to not only adapt it to the harsh Midwest climate, but also justify its viability.”
Ross also points to the vital need for teamwork. “Another struggle for the engineering firm was to design an exterior concrete precast structure with multiple openings. Extremely close coordination had to take place between engineering disciplines, architect, and the precast contractor,” he said.
Designing a naturally ventilated building that conformed to local code also challenged the team. For example, when it came to smoke evacuation strategies, “computational fluid dynamics analyses were commissioned to show that smoke could be effectively vented from the structure,” said architect of record Rick McCarthy, AIA, of Burnell Cassell Assocs., Elgin, Ill.
Natural ventilation is probably the most innovative aspect of the design. The building draws cool air at the lower level, circulates it throughout the building through various routes, and exhausts the air through roof terminals. Because of the extreme Midwest climate, a fully natural ventilation system was not possible. Consequently, mechanical engineers designed a hybrid system that minimizes the use of conventional heating and cooling, with operation in the natural mode for as much of the year as possible, but engaging the mechanical mode when the need arises.
There is a significant amount of engineering involved in the design of such a system, and the end product is a building that behaves as a single integrated system.
High school makes the lifecycle grade
Kinard Junior High School's design almost makes you want to go back to school just to check out the building. The facility incorporates thermal advanced insulating systems, daylighting, lighting controls, and geoexchange heat pump technology with exhaust air heat recovery ventilation systems. A building automation system monitors and controls engineered systems throughout the 117,000-sq.-ft building.
“Poudre School District (PSD) is very sensitive to total lifetime cost impacts of the design, construction, operation, and maintenance requirements, keeping in mind the total lifecycle costs rather than focusing primarily on the lowest first costs,” said Eric Young, PE, president of EMC Engineers Inc. and lead mechanical engineer on the project.
This was the fourth project that project architect, RB+B Architects, Fort Collins, Colo., designed under PSD sustainability guidelines. EMC was selected to provide three separate areas of service for this project: energy analysis, mechanical design, and commissioning. PSD selected EMC's energy team to help establish energy and sustainable goals for the facility, to create an energy model, and to update the model and advise the design team throughout the design process as relevant architectural and MEP systems features were determined. EMC also was selected for its experience in designing high-performance geoexchange systems. Finally, the firm was responsible for co-commissioning the building, working closely with Architectural Energy Corp., Boulder, Colo.
The district challenged the design team not only to explore ways to make this project even more energy efficient than previous schools, but also to make it exceptionally easy to build and maintain.
“The budget for the entire project was $17.45 million and the building was completed for a total cost of $17.5 million,” Young said. “The cost of the mechanical and plumbing portions of the project, including the geoexchange borefield, was $2.2 million, It came in on budget, equaling $18.86/sq. ft, a very competitive construction cost for this type of system.”
PSD documented the energy performance of this school for one complete year from July 2006 through June 2007, and tracked its performance against another conventional, similar-sized junior high school in the district. Electrical and gas savings can be summarized by the amount of energy used in one year per square foot for each school: Kinnard's 24.8 kBtu/sq. ft/yr compared to 55 kBtu/sq. ft/yr for the other school—an energy cost savings of approximately $30,000 in the first year of operation.
Stu Reeve, energy manager for PSD, echoes the excitement in the performance results. “Based on previous high-performance schools in PSD, we increased our expectations and performance goals for this project and EMC exceeded them all,” Reeve said.
Source: Consulting-Specifying Engineer
Standard Refrigeration Co. Inc.'s Guaynabo, Puerto Rico, facility was getting old. Real estate costs were skyrocketing. The shared office and manufacturing space just wasn't cutting it any more. The mechanical/electrical contracting firm, founded 60 years ago, had to move.
But firm officials didn't want just to build a new facility—they wanted a unique, sustainable building. The firm decided to acquire 5 acres of industrial set-aside land on the outskirts of San Juan. They acquired land in 1999, and completed the permit acquisition in 2004. Construction of the administrative building began in 2005, with occupancy beginning in 2006.
Finally, the crowning glory of the project came on Sept. 21, 2006, when the facility achieved a platinum rating under USGBC LEED NC Version 2.1 for new construction—the first building in Puerto Rico, and the first in the Caribbean, to attain this highest LEED certification level.
“The greatest challenge on the project was complying with requirements for LEED platinum status,” said Jorge Ledon Webster, PE, lead mechanical engineer on the project. “A lot of effort was put into providing a first-class interior environment requiring minimal energy costs. The LEED process requires a lot of documentation.”
The two-story building is a 9,600-sq.-ft footprint with 12,000 sq. ft of air conditioned area for offices, cafeteria and storage areas. In addition to being designed to LEED NC Version 2 requirements, the design process also adhered to ASHRAE 90.1-1999 for energy efficiency, ASHRAE 55-1995 for thermal comfort for human occupancy, and ASHRAE 62.1-2001 standard for ventilation. The main incentive for the new building was to achieve a substantial energy use reduction when compared with the firm's existing facility in Guaynabo.
Conserving energy
Energy conservation measures incorporated into the design including:
Lighting upgrade: With an illumination-level calculation program, and using minimum illumination level requirements of 50 lumens at all desktops, the total Watts per square foot were reduced by 0.78 W/sq. ft. In addition, all offices and open areas have T8 lamps with high-efficiency tubes and occupancy sensors. All walls have a reflectivity of 75% and ceilings have a reflectivity of 85%.
Insulation upgrade: In addition to the minimum requirements of ASHRAE 90.1-1999, the roof insulation was increased from R19 to R30 with a reflectivity of 92% and the walls from U = 0.58 and no R value requirement to a U = 0.089 and an R11.25.
Condensing unit efficiency upgrade: R410A units with dual speed compressors and 60,000 Btuh capacity with an 11.35 EER were installed (ASHRAE 90.1 minimum requirement is 9.7 EER).
Heat recovery: An energy recovery unit (enthalpy wheel) with an 85% efficiency and capable of handling 125% of the required outside air was included in the system. In addition, the hot water for the reheat coil in the air conditioning units is obtained from desuperheaters for each of four compressors. Solar panels are connected in series for additional reheat capacity.
High efficiency fans: The air conditioning unit has an adjustable-pitch vane axial fan with a static efficiency greater than 75%. ASHRAE 90.1 requires a maximum of 1.7 hp per 1,000 cfm for variable air volume (VAV) systems. The design used 0.675 hp per 1,000 cfm.
Fenestration: Double glass windows with clear glass inside and low-E glass outside with U = 0.26, exceeding ASHRAE 90.1 requirements. In addition, exterior metal shadings cover all glass areas for a substantial improvement on the solar heat gain coefficient requirements.
Exhaust and supply fans: The building exhaust and the outside air make-up use the fans of the energy recovery unit and are both served by variable frequency drives for higher energy efficiencies. Electrical efficiencies
“Our new building consumes so much less electricity than our previous building that the electrical savings alone will pay for the cost of the new building in 10 to 15 years at today's electricity rates,” said Juan S. Quintana, president of Standard Refrigeration. Strategies employed in this project yielded the results for electricity usage shown in Table 1.
Using the LEED-NC Version 2.1 criteria, where receptacles are not considered, the electricity savings is in excess of 70% when compared with ASHRAE 90.1-1999. The building management system of the new facility, along with a separate energy monitoring system, provided the electricity use data shown in Table 2. For the period from July 15, 2006, to July 15, 2007, the results of a comparison between design and actual use are shown in Table 3.
The hours of use and the square footage used in the model defined the difference in design vs. actual use of electricity for the receptacles. The complete building area should have been used in design for the receptacles rather than the air conditioned areas. The building receptacles serve refrigerators, water coolers, vending machines, uninterruptible power supplies, photocopiers, and other electrical units that consume electricity 24 hours per day.
For receptacles design: 12,000 sq. ft x 2,496 h x 0.66 W/sq. ft = 19,768 kWh
For receptacles actual: 19,200 sq. ft x 8,760 h x 0.29 W/sq. ft = 48,776 kWh.
The actual number of hours increased because they had to start up the unit two hours earlier every day, used the unit during the lunch hour, and used it for two additional hours every day in the afternoon, which lead to the difference between design and actual electricity use for the air conditioning system. The number of hours used in the design model is 2,496, but the actual number of hours is 4,400: 4,400/2,496 x 51,885 kWh = 91,464 kWh
Mechanical integration
The air conditioning system consists of an air-handling unit (AHU) with a VAV adjustable-pitch vane axial fan with variable volume boxes to maintain static pressure and variable volume diffusers in every location. The AHU has a DX cooling coil that is vertically split intertwined and has a double circuit, top and bottom. The AHU is a draw-through type, and each coil section closest to the fan has an individual 5 TR (tons of refrigeration) condensing unit connected to it that runs continuously while the fan is operating. Each of the other coil sections of the split coil is connected to a variable speed 5 TR condensing unit and responds to leaving air temperature (set at 53 F).
The variable speed condensing units are not allowed to cycle more than six times per hour. If the building temperature drops below 73 F, the VAV reheat water pump operates to raise the building return air temperature through the reheat coil. This combination of sequences allows the A/C system to maintain 72 F +/-1 F and 50% +/-5% relative humidity.
Outside air is forced into the AHU return plenum by a VAV energy recovery unit that is capable of 125% of the required air for ventilation. The AHU has (MERV 14) 85% efficient permanent filters and 40% throw away pre-filters. It also has UV-C lights in the return air plenum using the intensity recommendations from “Immune Building Systems Technology” (Wladyslaw Jan Kowalski, McGraw-Hill, 2002).
All ductwork in the building is galvanized sheet metal double-wall with solid interior liner and fiberglass insulation sandwiched between duct walls. Additionally, the inner duct liner is covered with a technology that liberates silver ions and prevents bacterial growth inside the ducts.
All VAV diffusers (thermafusers) were placed so as to achieve an air diffusion performance index of 90 or greater. Areas with more than one occupant have a thermostat that can bypass the VAV serving the area and convert the VAV to temperature-controlled for a period of 3 hours. A Web-based monitoring system samples seven different areas of the building for temperature, relative humidity, carbon monoxide, carbon dioxide, VOCs, and particulate. This continuous sampling process also reports to the energy management system.
In order to verify the particulate reported by the monitoring system, the engineers brought in a particle counter and the area sampled at random reported as ISO class 8 clean room. The ratio is maintained at a maximum of 1.0 cfm/sq. ft and a minimum of 0.7 cfm/sq. ft by the VAV system. The ratio of exhaust air to intake air is controlled using VAV units in both supply and exhaust fans to achieve positive building pressurization, adequate exhaust control, and minimum ventilation requirements at all times. Only if the carbon monoxide in the building exceeds 800 parts per million will the minimum ventilation rate be exceeded while always maintaining building pressurization.
Not only did the design team create a high-performance facility in terms of energy efficiency, but they also maximized efficiencies with respect to operation and maintenance. The AHU, energy recovery unit, condensing units, desuperheaters, reheat water tank, reheat pump and domestic solar hot water collectors all are located on a single pad outside the building for ease of maintenance. And the commissioning process verified each and every item of the HVAC and plumbing system.
Design uniqueness
“The positive environmental impacts that result from the design of our new building are significant and many,” Quintana said, “including condensing units that use R-410A refrigerant; electrical savings of 70% that substantially reduce carbon dioxide generation; and recycling of materials such as glass, paper, aluminum, cardboard, electrical lamps, printer cartridges, car batteries, oil, cellular phones, sheet metal, car tires, wood pallets, and grass.”
In addition, light pollution is eliminated by keeping the illumination within the site; all storm water is strained for removal of oil residue and some phosphorus; rain water is used for toilets and urinals; and the facility's own sewage treatment plant operates on evapotranspiration, which does not impact acquifer recharging. Storm water is retained in an underground rechargeable tank that slowly releases water during a 72 h timeframe so that water will not affect the level of the creek close to our site.
“We feel that our building is really unique,” Quintana said. “It is located in Puerto Rico without the benefits of using cold outside air for air conditioning at any time during the year. Yet still, we have achieved 750 sq. ft/ton.
“The greatest reward was that project goals were accomplished, and that the owner obtained substancial savings from energy and water measures that were implemented during the design process,” he said. “The coordination between the owner, which in this case was the contractor, and the rest of the design team was a great plus for implementing all the energy savings into the project.”
Because the owners of the facility are in the MEP business themselves, they began this project with a strong notion of what could be achieved, and challenged their design team with the task of far surpassing their existing building in energy use reduction. And the design team did a “platinum” job of meeting the challenge.
End use Design case (kWh) Budget case (kWh)
Electrical receptacles 19,740 19,740
Lighting 29,823 48,232
Space cooling 42,168 116,703
Fans/pumps 9,717 110,028
Date Receptacles First floor Second floor A/C
07/15/2006 40 x 106 W 6 x 106 W 6 x 106 W 44 x 106 W
07/15/2007 88 x 106 W 17 x 106 W 18 x 106 W 83.5 x 106 W
Use Design (kWh) Actual (kWh)
Lighting 29,823 23,000
Receptacles 19,740 48,000
A/C 51,885 83,500
Natural ventilation makes this library coolest building on campus
Architecture rules at this new Judson University building, which houses an expanded library and the division of art, design, and architecture. “Seeking a facility worthy of an evolving architecture program that is seeking accreditation, the university conducted an international design competition,” said Norm Bower, KJWW public relations coordinator. London-based architect Alan Short of Short and Assocs., a pioneer in low-energy, naturally ventilated, and passively cooled buildings, designed the facility.
The design team's challenge was to treat light and humidity issues in a library and art environment, where these factors could seriously damage the contents of the 88,000-sq.-ft building. Dominant energy-conscious features of the building are its photovoltaic, natural ventilation, and natural daylighting systems. Optimizing solar gains in the spring and fall is intended to allow the building to run naturally, with little or no mechanical intervention, for six or more months of the year. The building is expected to earn a USGBC LEED silver rating.
“The greatest challenge as an HVAC engineer on this project was taking the vision of placing a naturally ventilated building in the middle of the Midwest,” said Wade Ross, PE, lead mechanical engineer on the project. “Although the system works well in Northern Europe, we had to not only adapt it to the harsh Midwest climate, but also justify its viability.”
Ross also points to the vital need for teamwork. “Another struggle for the engineering firm was to design an exterior concrete precast structure with multiple openings. Extremely close coordination had to take place between engineering disciplines, architect, and the precast contractor,” he said.
Designing a naturally ventilated building that conformed to local code also challenged the team. For example, when it came to smoke evacuation strategies, “computational fluid dynamics analyses were commissioned to show that smoke could be effectively vented from the structure,” said architect of record Rick McCarthy, AIA, of Burnell Cassell Assocs., Elgin, Ill.
Natural ventilation is probably the most innovative aspect of the design. The building draws cool air at the lower level, circulates it throughout the building through various routes, and exhausts the air through roof terminals. Because of the extreme Midwest climate, a fully natural ventilation system was not possible. Consequently, mechanical engineers designed a hybrid system that minimizes the use of conventional heating and cooling, with operation in the natural mode for as much of the year as possible, but engaging the mechanical mode when the need arises.
There is a significant amount of engineering involved in the design of such a system, and the end product is a building that behaves as a single integrated system.
High school makes the lifecycle grade
Kinard Junior High School's design almost makes you want to go back to school just to check out the building. The facility incorporates thermal advanced insulating systems, daylighting, lighting controls, and geoexchange heat pump technology with exhaust air heat recovery ventilation systems. A building automation system monitors and controls engineered systems throughout the 117,000-sq.-ft building.
“Poudre School District (PSD) is very sensitive to total lifetime cost impacts of the design, construction, operation, and maintenance requirements, keeping in mind the total lifecycle costs rather than focusing primarily on the lowest first costs,” said Eric Young, PE, president of EMC Engineers Inc. and lead mechanical engineer on the project.
This was the fourth project that project architect, RB+B Architects, Fort Collins, Colo., designed under PSD sustainability guidelines. EMC was selected to provide three separate areas of service for this project: energy analysis, mechanical design, and commissioning. PSD selected EMC's energy team to help establish energy and sustainable goals for the facility, to create an energy model, and to update the model and advise the design team throughout the design process as relevant architectural and MEP systems features were determined. EMC also was selected for its experience in designing high-performance geoexchange systems. Finally, the firm was responsible for co-commissioning the building, working closely with Architectural Energy Corp., Boulder, Colo.
The district challenged the design team not only to explore ways to make this project even more energy efficient than previous schools, but also to make it exceptionally easy to build and maintain.
“The budget for the entire project was $17.45 million and the building was completed for a total cost of $17.5 million,” Young said. “The cost of the mechanical and plumbing portions of the project, including the geoexchange borefield, was $2.2 million, It came in on budget, equaling $18.86/sq. ft, a very competitive construction cost for this type of system.”
PSD documented the energy performance of this school for one complete year from July 2006 through June 2007, and tracked its performance against another conventional, similar-sized junior high school in the district. Electrical and gas savings can be summarized by the amount of energy used in one year per square foot for each school: Kinnard's 24.8 kBtu/sq. ft/yr compared to 55 kBtu/sq. ft/yr for the other school—an energy cost savings of approximately $30,000 in the first year of operation.
Stu Reeve, energy manager for PSD, echoes the excitement in the performance results. “Based on previous high-performance schools in PSD, we increased our expectations and performance goals for this project and EMC exceeded them all,” Reeve said.
Source: Consulting-Specifying Engineer
Labels:
building construction,
Caribbean,
green technology
Subscribe to:
Posts (Atom)